Gas Burner Riello RS 68-120-160-200

Rp. 120.000.000
Update Terakhir
16 Mar 2023
Negara Asal
Indonesia
Pembelian Min
10 unit

Spesifikasi Gas Burner Riello RS 68-120-160-200


Distributor Burner Riello Indonesia


RIELLO RS 68-120-160-200

Gas Burner Riello RS

TWO STAGE GAS BURNERS 

RS 28 81/163 ÷ 325 kW 

RS 38 105/232 ÷ 440 kW 

RS 50 116/290 ÷ 580 kW 

RS 70 192/465 ÷ 814 kW 

RS 100 232/698 ÷ 1163 kW 

RS 130 372/930 ÷ 1512 kW 

RS 190 470/1279 ÷ 2290 kW


The RS series of burners covers a firing range from 81 to 2290 kW, and they have been
designed for use in hot or superheater water boilers, hot air or steam generators,
diathermic oil boilers. 

Operation is "two stage"; the burners are fitted with an electronic device STATUS PANEL,
which supplies complete diagnostic: hour meter, ignition meter, identification of trouble
shooting. 

Optimisation of sound emissions is guaranteed by the use of fans with forward inclined
blades and sound deadening material incorporated in the air suction circuit.
The elevated performance of the fans and combustion head, guarantee flexibility of use
and excellent working at all firing rates.
The exclusive design ensures reduced dimensions, simple use and maintenance. A wide
range of accessories guarantees elevated working flexibility.


GAS TRAINS

The burners are fitted with a butterfly valve to regulate the fuel
delivery on 1st and 2nd stage, controlled by a variable profile
cam servomotor.
Fuel can be supplied either from the right or
left hand sides.
The gas train can be selected to best fit system
requirements depending on the fuel output
and pressure in the supply line.
The gas train can be “Multibloc“ type
(containing the main components in a single
unit) or “Composed” type (assembly of the
single components).


Gas trains are approved by standard EN 676 together with the burner.
The overall dimensions of the gas train depends on how they are constructed. The following table
shows the maximum dimensions of the gas trains that can be fitted to RS burners, intake and outlet
diameters and seal control if fitted.
Please note that the seal control can be installed as an accessory, if not already installed on the gas
train.
The maximum gas pressure of gas train “Multibloc” type is 300 mbar, and that one of gas train
“Composed” type is 500 mbar.

Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

rs 28,38,50,70,100,130,190.pdf

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Minta Penawaran
Produk Siap di Pesan
Rp 0
1
Logo IDT
Chatbot